MCB 1P 6/10kA C-10A 1M

Other Hager Products: | 25A Earth Leakage | 10 Way DB | 16A Circuit Breaker |

Hager - NF110A Circuit Breaker 10A

MCB 1P 6/10kA C-10A 1M

Architecture
  • Number of protected poles - 1
  • Number of poles - 1 P
  • Type of pole - 1 P
  • Curve - C
Main electrical features
  • Rated short circuit breaking capacity Icn AC according IEC60898-1 - 6 kA
  • Rated operational voltage Ue - 230 / 400 V
  • Frequency - 50/60
Voltage
  • Rated insulation voltage - 500 V
  • Rated impulse withstand voltage - 4000 V
Electric current
  • Rated current - 10 A
  • Rated service breaking capacity Ics AC according IEC 60898-1 - 6 kA
  • min/maxi threshold value of the AC thermal operation - 1.13 / 1.45 In
  • Magnetic regulating currrent - 5 / 10 In
  • min/maxi threshold value of the DC magnetic operation - 7 / 15 In
  • min/maxi threshold value of the DC thermal operation - 1.13 / 1.45 In
  • Breaking capacity on 1 pole for IT 400V NF 60947-2 - 3 kA
  • Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1 - 6 kA
  • Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2 - 10 kA
  • Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2 - 10 kA
Dimensions
  • Depth of installed product - 70 mm
  • Height of installed product - 83 mm
  • Width of installed product - 17.5 mm

Price: R146.45

2 in stock

Price: R146.45

2 in stock

Hager - NF110A Circuit Breaker 10A

MCB 1P 6/10kA C-10A 1M

Architecture
  • Number of protected poles - 1
  • Number of poles - 1 P
  • Type of pole - 1 P
  • Curve - C
Main electrical features
  • Rated short circuit breaking capacity Icn AC according IEC60898-1 - 6 kA
  • Rated operational voltage Ue - 230 / 400 V
  • Frequency - 50/60
Voltage
  • Rated insulation voltage - 500 V
  • Rated impulse withstand voltage - 4000 V
Electric current
  • Rated current - 10 A
  • Rated service breaking capacity Ics AC according IEC 60898-1 - 6 kA
  • min/maxi threshold value of the AC thermal operation - 1.13 / 1.45 In
  • Magnetic regulating currrent - 5 / 10 In
  • min/maxi threshold value of the DC magnetic operation - 7 / 15 In
  • min/maxi threshold value of the DC thermal operation - 1.13 / 1.45 In
  • Breaking capacity on 1 pole for IT 400V NF 60947-2 - 3 kA
  • Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1 - 6 kA
  • Rated ultimate short-circuit breaking capacity Icu under 230V AC IEC 60947-2 - 10 kA
  • Rated ultimate short-circuit breaking capacity Icu under 415V AC IEC 60947-2 - 10 kA
Dimensions
  • Depth of installed product - 70 mm
  • Height of installed product - 83 mm
  • Width of installed product - 17.5 mm